Shenzhen Must Power Limited
Main products:UPS, Inverter
Products
Contact Us
  • Contact Person : Ms. yuan tina
  • Company Name : Shenzhen Must Power Limited
  • Tel : 86-755-29109533
  • Fax : 86-755-29022690
  • Address : Guangdong,shenzhen,Building D,Huachuangda Industrial Park,Hangchen Road,Gushu, Xixiang Town, Baoan District
  • Country/Region : China
  • Zip : 518100

New model inverter 230v 12v 600w

New model inverter 230v 12v 600w
Product Detailed
1.LCD pure sine wave inverter 2.Built in charger, max 20amp charge current 3.AVR function 4.Low frequency

New model inverter 230v 12v 600w

Main featrues:

1. sine wave power inverter

2.12/ 24VDC optional

3.Pure sine wave.

4.Low frequency, inbuilt transformer.

5.AVR function

6.Charge current Max.20A.

7. Support inductive load, motor, generator.

8. Input range: 145-275vac

9. output: 230vac+/-10%

10. RS232 available

11. LCD panel

12. transfor time: 5ms

13.protection: automatic self-test, discharge protection, over charging protection, short-circuit protection.low voltage, over voltage,over load,over heating protection etc.

 Technology sepcification:

Model115V Models230V Models
OUTPUT
Power Levels crated at nominal inputs300W;500W;600W; 800W ;1000W300W;500W;600W; 800W;1000W
Output Voltage110V/115V/120V Selectable220V/230V/240V Selectable
Voltage WaveformPure Sine wave
Crest Factor3:1
Output Frequency(Synchronized to Mains)Auto Select for 50/60Hz;47Hz ~ 55Hz for 50Hz nominal;56Hz ~ 65Hz for 60Hz nominal
Regulation (Nominal)±10% typical of nominal voltage
Regulation(Battery mode)±3% of selected output voltage (adjustable with the remote set-up software)
Transfer time5ms Typical
Over current protectionOver load alarm level 100% ~ 120%;Over load shutdown level 120% ~ 190%(Adjustable by using the remote set-up software)
INPUT
Nominal Voltage110V/115V/120V Selectable220V/230V/240V Selectable
Input Frequency47Hz ~ 65Hz, 50/60Hz auto-sensing
Efficiency (Normal mode)>95%
Noise FilteringFull time EMI/RFI filtering
Over current protectionRe-settable over current protector;500VA ~ 5000VAAC Fuse:500VA / 1500VA Re-settable over current protector:1500VA ~10kVA
Voltage Range75V ~ 155V145V ~ 310V
AVR Range(2 Bucks, 2 Boosts)Enhanced Buck: +28% of selected nominal voltage;Buck mode: +10% of selected nominal voltage;Boost mode: -10% of selected nominal voltageEnhanced Boost: -25% of selected nominal voltage
Surge Protection500VA / 1500VA:216 Joules1500VA ~ 5000VA:324 Joules500VA / 1500VA:220 Joules1500VA ~10000VA:440 Joules
BATTERY
Battery typeLead-Acid 7Ah~200Ah (Recommended)Lead-Acid7Ah~200Ah (Recommended)
DC Voltage300W/600W/800W 1000W:12Vdc1200W/1500W:24Vdc500VA / 1000VA:12Vdc1500VA:24Vdc
Typical backup timeNo Limit
Charging methodSmart pulse charging with two charging modes:Quick charging when batteryis not fully charged;trickle charging when battery is 90% fully charged.
Maximum charging current300W-1500W:15A300W-1500W:25A
Average chargingvoltage for each batteryQuick charging mode:14V maximum.Trickle charging mode:13.5V (adjustable with the remote set-up software)
ProtectionOver current protection & Over charging voltage protection (SCR control)Thermal protection (CPU control)When temperature inside the unit is over 45 , charger will stop charging for 2minutes followed by an 2 minutes charging. The cycle will be repeate
MonitoringSmart monitoring & warning for failed battery or open-circuit battery.Auto-detection each time when power on or every 6 days.
SOLAR CHARGER (OPTIONAL)
Rating voltage12V / 24V / 48V12V / 24V / 48V
DC input range12V model:12 ~ 21Vdc; 24V model:24 ~ 42Vdc; 48V model:48 ~ 84Vdc
Charging methodConstant voltage with current limiting by PWM control
Charging voltage12V model:13.5Vdc; 24V model:27.0Vdc; 48V model:54.0Vdc
Power rating12V model:500W (13.5Vdc @ 37A); 24V model:1000W (27.0Vdc @ 37A)48V model : 1000W (54Vdc @ 18.5A)
ProtectionDC input polarity protection, DC input short circuit protection( when battery isconnected), DC output over current protection
COMMUNICATION&MANAGEMENT
Standard Interface portUPSilon2000 compatible; optional for RS232 .
Optional Interface partRJ45 (Surge protection), DB9,
Control panelLCD or LED Selectable
Audible alarmAlarm on battery:Low battery & Battery over voltageAlarm on abnormal operation:Over load, Short-circuit, & Over heat
Green mode function(Auto-shut-off in blackout)1% to 14% of full load (adjustable by using the remote set-up software)The default setting is OFF.
Cooling fan controlAuto on / off, controlled by temperature & operation mode
ENVIRONMENTAL & SAFETY
Operating TemperatureUp to 1500 meters:0 °C to 40 °C (32 °F to 104 °F)
Transit/storage Temp.-15 °C to 55 °C (5 °F to 131 °F)
Relative Humidity5 - 95% non condensing
Operating Altitude0 ~ 3000 meters
Quality control systemISO 9001:2000, ISO 14002-2004
PHYSICAL
AppearanceSize(mm) L x W x H312*262*118
Weight(Kg)300W:7.0kg ;500W: 9.0kgs; 600W : 10.5kg ; 800W :12.5kg; 1000W:12.5KG
Carton BOX(mm)Lx WxH415*348*205(1 piece)
G.W:(Kg) 300W:7.5kg ; 500W: 8.3kgs; 600W :11.0kg ;800W :13.0kg;1000W:13.0KG

New model inverter 230v 12v 600w